P Monitor CMS8000 & Pr/Nibp/Spo2/Tem/ECG
R20553,09
The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate.
Description
P Monitor CMS8000 & Pr/Nibp/Spo2/Tem/ECG
P Monitor CMS8000 & Pr/Nibp/Spo2/Tem/ECG
Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 12.1” color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.
This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.
Functions:
- Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
- ECG Heart rate(HR)
- ECG waveform
- Arrhythmia and ST-segment analysis
- RESP Respiration rate(RR)
- Respiration waveform
- SpO2 Oxygen saturation(SpO2)
- Plethysmogram(PLETH) waveform
- Pulse rate(PR)
- Bar graph
- NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
- TEMP T1, T2, TD
- IBP(optional) CH1:SYS,DIA,MAP
- CH2:SYS,DIA,MAP
- IBP waveform
- CO2 EtCO2
- InsCO2:Inspired Minimum CO2
- AwRR:Air Way Respiration
- It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc
Features:
- 12.1” TFT color LCD, multi-language interface
- Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
- All-round monitor for adult, pediatric and neonate.
- With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
- Finish all operations by keys and knobs.
- Maximum 8-channel waveform synchronous display.
- Display 7-lead ECG waveform on one screen, cascade ECG waveform display
- Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
- Heart rate variability (HRV) analysis function
- NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
- Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
- Drug concentration calculation and titration table functions.
- One-touch printing of trend graph
- Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
- AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
- Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary)
Performance:
â–²ECG:
- Lead mode: 3-lead or 5-lead
- Lead selection: I, II, III, aVR, aVL, aVF, V
- Waveform: 5-lead, dual-channel
- 3-lead, single-channel
- Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
- Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
- HR:
- Measurement and alarm range: 15~350 bpm
- Accuracy: ±1 % or ±1 bpm, whichever is greater
- Alarm accuracy: ± 2 bpm
- Resolution: 1 bpm
- ST-segment monitoring:
- Measurement and alarm range: -2.0 mV ~ +2.0 mV
- Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
- Other range: unspecified
- Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
- PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
- Pacemaker: yes
- Method: R-F(RA-LL) Impedance
- Respiration rate:
- Measurement and alarm range: 0~150 rpm
- Resolution: 1 rpm
- Measurement accuracy: ±2 rpm
- Alarm accuracy: ±3 rpm
- Apnea alarm: 10~40s
- Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
â–²NIBP:
- Method: Oscillometry
- Mode: Manual/AUTO/STAT
- Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
- Measurement period in STAT mode: 5 minutes
- Measurement and alarm range: 10 ~ 270 mmHg
- Resolution: 1 mmHg
- Cuff pressure accuracy: ±3 mmHg
- Measurement accuracy:
- Maximal mean deviation: ±5 mmHg
- Maximal standard deviation: 8 mmHg
- Over-pressure protection:
- Adult mode: 297±3 mmHg
-  Pediatric mode: 240±3 mmHg
-  Neonatal mode: 147±3 mmHg
â–²SpO2:
- Measurement and alarm range: 0 ~ 100%
- Resolution: 1%
- Measurement accuracy: 70%~100%: ±2%;
- 0%~69%: unspecified
â–²PR:
- Measurement and alarm range: 30 ~ 250 bpm
- Measurement accuracy: ±2 bpm or ±2%, whichever is greater
â–²TEMP:
- Channel: dual-channel
- Measurement and alarm range: 0 ~ 50℃
- Resolution: 0.1 ℃
- Accuracy: ±0.1 ℃