Specifications

Model KL-605T
Syringe Size 5, 10, 20, 30, 50/60 ml
Applicable Syringe Compatible with syringe of any standard
VTBI 0.1-1200 ml (in 0.1, 1, 10 ml increments)
Flow Rate Syringe 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)Syringe 10 ml: 0.1-300 ml/h

Syringe 20 ml: 0.1-600 ml/h

Syringe 30 ml: 0.1-800 ml/h

Syringe 50/60 ml: 0.1-1200 ml/h

Bolus Rate 5 ml: 0.1-100 ml/h (in 0.01, 0.1, 1, 10 ml/h increments)10 ml: 0.1-300 ml/h

20 ml: 0.1-600 ml/h

30 ml: 0.1-800 ml/h

50/60 ml: 0.1-1200 ml/h

Anti-Bolus Automatic
Accuracy ±2% (mechanical accuracy≤1%)
Infusion Mode Memory modeFlow rate: ml/min, ml/h

Time-based

Body weight

KVO Rate 0.1-1 ml/h (in 0.01 ml/h increments)
Alarms Occlusion, near empty, end program, low battery, end battery,AC power off, motor malfunction, system malfunction, reminder alarm,

pressure sensor error, syringe installation error, syringe drop off

Additional Features Real-time infused volume, automatic power switching,automatic syringe identification, mute key, purge, bolus, anti-bolus,

system memory, history log

Drug Library Available
Occlusion Sensitivity High, medium, low
History Log 50000 events
Power Supply, AC 110/230 V, 50/60 Hz, 20 VA
Battery 14.8 V, rechargeable
Battery Life 8 hours at 5 ml/h
Working Temperature 5-40℃
Relative Humidity 20-90%
Atmospheric Pressure 700-1060 hpa
Size 245*120*115 mm
Weight 2.5 kg
Safety Classification Class Ⅱ, type BF

Description

 

Syringe Pump KL-605T

Intravenous infusion pump

Should be compact weighing 2.5 Kg color TFT display Syringe sizes 5,10,20,30,50/60 ml Should be compatible with syringe of any brand standard Flow rate range Syringe 5 ml 0.1-100 ml/h in 0.01, 0.1, 1, 10 ml/h increments Syringe 10 ml 0.1-300 ml/hSyringe 20 ml 0.1-600 ml/h Syringe 30 ml 0.1-800 ml/h Syringe 50/60 ml 0.1-1200 ml/h Should have Bolus rate5 ml 0.1-100 ml/h in 0.01, 0.1, 1, 10 ml/h increments10 ml 0.1-300 ml/h20 ml 0.1-600 ml/h30 ml 0.1-800 ml/h50/60 ml 0.1-1200 ml/h Anti-Bolus Mechanism Flow rate setting ml/Min, ml/h Should have infusion modes- Flow based, Time based, body weight mode Should have Body weight rate calculation in g/kg/min, g/kg/h, mg/kg/min, mg/kg/h Should have KVO rate 0.1-1 ml/h in 0.01 ml/h increments Should have alarms for Occlusion, Near empty, End programme, low battery, A/C power off, motor malfunction, System malfunction, Pressure sensor error, Syringe drop off.

Other Specifications
Material FIBRE
Technolgy SERVO MECHANISM
Capability Of Motioring Of Empty Intravenous Bags Or Bottles Yes
Fitting Of Device On The IV Bottle And Bag Yes
I.R Sensor To Detect The Abnormilty In I.V Bag Or Bottle Yes
Sound Alarm Provided Yes
Power Sources Battery operated
Details Of Battery In Use LITHIUM ION
Life Of Battery TWO YEARS
Packing Individual
Certification ISO/European-CE